HIOKI CLAMP ON EARTH TESTER FT6380-50

HIOKI CLAMP ON EARTH TESTER FT6380-50
Brand: HIOKI
Category: Digital Meters

The FT6380-50 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.

The FT6380-50 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
Clamp on the earth cable. The instrument has two cores for voltage injection and current measurement.
1. The voltage transducer injects a defined voltage into the multi-grounded system.
2. From the defined voltage and measured current, the total circuit loop resistance is calculated in the following equation.
Rx + 1/ [ (1/R1) + (1/R2) + (1/R3) + (1/R4) + ... ] = V/I
In a typical multi-grounded system, the parallel resistance value is small enough to be ignored and the equation as referred on the left can be simulated as follows.
Rx = V/I

The dramatically slim 0.79 inch (20mm) jaws let you finish your job easily and efficiently.

The new FT6380-50 is compatible with the Wireless Adapter Z3210 (optional).
When the Z3210 is installed, Bluetooth® wireless communication is enabled.
The measurement data can be transferred to the dedicated free application GENNECT Cross or your Excel® files and reports.

Measurement principle Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value.
Earthing resistance range 0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression: Less than 0.02 Ω, 
Accuracy: ±1.5 % rdg. ±0.02 Ω
AC Current range 20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA, 
Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less)
Maximum input current (Current measurement) 100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50 Hz/60 Hz, requires derating at frequency)
Maximum rated terminal-to-ground voltage 600 VAC measurement category IV (anticipated transient overvoltage 8000 V)
Memory function 2000 data
Alarm function For resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold.
Harmonic levels [With Z3210 installed] Current harmonic levels up to 30th, Content factor, Total harmonic distortion ratio
*Harmonics can be displayed with our free app GENNECT Cross.
Other functions Data hold, Backlight, Filter, Auto power save, Wireless communication (without Z3210 installed))
Display LCD, Max. 2,000 count Display refresh rate: Approx. 2 times/sec.
Dust-proof and waterproof IP40 (EN60529) With Jaws Closed
Power supply LR6 alkaline battery × 2
Continuous operating time Approx. 40 hours (25 Ω measurement, backlight off, without Z3210 installed)
Approx. 35 hours (25 Ω measurement, backlight off, with Z3210 installed and using wireless communications)
Maximum measurable conductor diameter φ 32 mm (1.26 in)
Dimensions and mass 73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69 in) D, 620 g (21.9 oz)
Included accessories Carrying case, Resistance check loop (1 Ω±2%, 25Ω±1%), Strap, LR6 alkaline battery × 2, Instruction manual